B–61863E/15
11. INTERRUPT–TYPE
PMC FUNCTION
PMC SEQUENCE PROGRAM
409
Machine instructions not usable in the interrupt program
(1)TMR (timer), TMRB (fixed timer), and TMRC (timer)
The least input increment for the timer values is 8 ms, so it may not
be possible to measure time accurately.
(2)CTR (counter), CTRC (counter), DIFU (rising edge detection), DIFD
(falling edge detection)
Because the rising or falling signal edge is handled, it is necessary to
execute the interrupt program twice in order to check for signal
changes. Furthermore, the DIFU and DIFD outputs are held to 1 until
the interrupt program is executed again.
(3)DISPB (message display), EXIN (external data input), low–speed
WINDR/WINDW (NC window data read/write), and AXCTL (PMC
axis control)
It takes at least two cycles (one cycle = 8 ms) to complete the execution
of each of these instructions. In addition, the execution of the EXIN,
low–speed WINDR/WINDW, and AXCTL instructions involve
exclusive control. If the interrupt program is terminated before
completion, these instructions are disabled in the second–level
sequence program.
(4)CALL (conditional subprogram call) and CALLU (unconditional
subprogram call)
These instructions are unusable, in the same way as the conventional
first–level program.
11.3.6
Cautions