7. OPERATION (PMC–SB7)
B–61863E/15
STEP SEQUENCE FUNCTION
1052
(d)Definition of monitor
Position the cursor at the deletion and press [DELETE] key.
The settings of that number are deleted regardless of the cursor
position(”STEP NO.” or ”MONITOR”).
(e) Alteration of monitor
Position the cursor at the alteration position and input again.
Display the Ladder Diagram Editor screen from Program List Viewer
screen, Subprogram List Viewer screen, and Step Sequence Monitor
screen, by pushing [EDIT] key.
This screen is the same as ”5.1 LADDER DIAGRAM EDITOR
SCREEN” of ”V.FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION”.
Refer to the explanation for the details of that screen.
7.4
EDITING FUNCTION
OF LADDER
DIAGRAM