B–61863E/15
L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
APPENDIX
1543
(Example)
N600000 P1; Timer Number 1 T0
N600002 P20; Timer Number 2 T2
......
N600498 P32767; Timer Number 250 T498
N609000 P0; T9000
N609002 P0; T9002
......
609498 P0; T9498
*Note: The area from N609000 to N609498 is reserve and P0
should be set.
(3)Counter(C)
[Format]
N61xxxx Pnnnnn; Counter Reset Value, Counter Current Value
N: The numbers of counter address plus 610000. The ranges are
from N610000 to N610398 and from N615000 to N615198.
P: The counter value with decimal numeric. The effective
values from N610000 to N610398 are from 0 to 32767.
Counter Preset value and Counter Current value are output
alternately. The effective values from N615000 to N615198
are from 0 to 32767. Only Current values are output. Binary
data are always output regardless of the setting of BCD
format or binary format.
(Example)
N610000 P7; Counter Number 1 C0
N610002 P7; C2
......
N610396 P9999; Counter Number 100 C396
N610398 P0; C398
N615000 P7; Fixed Counter Number 1 C5000
N615002 P20; Fixed Counter Number 2 C5002
......
N615198 P9999; Fixed Counter Number 100 C5198
(4)Keep relay (K)
[Format]
N62xxxx Pnnnnn;
N: The numbers of keep relay address plus 620000. The ranges
are from N620000 to N620099 and from N620900 to
N620919.
P: The value of the keep relay with binary numeric. The
effective values from N620000 to N620099 are from
00000000 to 11111111. The effective values from N620900
to N620919 are also from 00000000 to 11111111.
(Example)
N620000 P00000000; K0
N620001 P11111111; K1
......
N620099 P10101010; K99