B–61863E/15
6. LADDER DIAGRAM MONITOR
AND EDITOR
PMC–NB6 MANIPULATION
717
The following table shows all monitor formats for each parameter of each
functional instruction.
NOTE
1 ”Variable” in ”Monitor Format” field means that this
parameter changes its size according to the other
parameter. Refer to the descriptions for each functional
instruction for detail.
2 Functional instruction with ”*” mark has Data table.
No. Name Parameter Monitor Format No. Name Parameter Monitor Format
1 END1 – –
18 XMOV
1 constant
2 END2 – – 2 4–digits BCD
3 TMR 1 special 3 4–digits BCD
4 DEC
1 2–digits BCD 4 4–digits BCD
2 constant
19 ADD
1 constant
5 CTR 1 special 2 4–digits BCD
6 ROT
1 constant 3 4–digits BCD
2 4–digits BCD 4 4–digits BCD
3 4–digits BCD
20 SUB
1 constant
4 4–digits BCD 2 4–digits BCD
7 COD *
1 constant 3 4–digits BCD
2 2–DIGITS BCD 4 4–digits BCD
3 4–digits BCD
21 MUL
1 constant
8 MOVE
1 constant 2 4–digits BCD
2 constant 3 4–digits BCD
3 2–digits HEX 4 4–digits BCD
4 2–digits HEX
22 DIV
1 constant
9 COM 1 constant 2 4–digits BCD
10 JMP 1 constant 3 4–digits BCD
11 PARI 1 1–byte binary 4 4–digits BCD
14 DCNV
1 no monitor
23 NUME
1 constant
2 no monitor 2 4–digits BCD
15 COMP
1 constant
24 TMRB
1 constant
2 4–digits BCD 2 special
3 4–digits BCD
25 DECB
1 constant
16 COIN
1 constant 2 variable binary
2 4–digits BCD 3 constant
3 4–digits BCD 4 2–digits HEX
17 DSCH
1 constant
26 ROTB
1 constant
2 4–digits BCD 2 variable binary
3 4–digits BCD 3 variable binary
4 4–digits BCD 4 variable binary
5 variable binary
6.1.5
Display Format for
Parameters