B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
B–61863E/15
APPENDIX
1162
[Description]
The CNC setting data can be read.
There are four types of setting data in the CNC: Bit setting data having
a definite meaning for each bit, byte setting data stored in bytes, word
setting data stored in 2–byte units, and double–word setting data stored
in 4–byte units. Therefore, the length of the read data varies according
to the setting data specified.
Note that bit setting data cannot be read in bit units. The eight bits (one
byte) for the setting data number must be read at a time.
For axis parameters, data for a specific axis can be read, or data for all axes
can be read at a time.
For details of setting data, refer to the Operator’s manual of the CNC.
[Input data structure]
Top address + 0
2
4
6
8
10
(Function code)
19
(Completion code)
—
(Need not be set)
(Data length)
—
(Need not be set)
(Data number)
N
(N = Setting data number)
(Data attribute)
M
(M = Axis number)
(Data area)
—
(Need not be set)
XX
42
M = 0 : No axis
M = 1 to n: A specific axis
M = –1: All axes
B.4.8
Reading Setting Data
(:Low–speed
Response)