E. WINDOW FUNCTION DESCRIPTION
(FS16–W)
B–61863E/15
APPENDIX
1466
[Description]
Parameter data in the CNC can be written.
There are four types of parameters in the CNC: Bit parameters having
a definite meaning for each bit, byte parameters holding 1–byte data, word
parameters holding 2–byte data, and double word parameters holding
4–byte data. Therefore, the length of the written data varies according to
the parameter specified.
Note that bit parameters cannot be written in bit unit. The eighth bits (one
byte) for the parameter number must be written at a time. This means that
when a bit needs to be written, the whole data for the corresponding
parameter number shall be read first, then the target bit in the read data
shall be written.
For axis parameters (servo parameters), data for a specific axis can be
written, or data for all axes can be written at a time.
Some parameters cause a P/S alarm 000 when data is written. (The power
must be turned off before continuing operation.)
Top address
(Function)
18
(Completion)
—
(Data length)
L
(Number)
N
(Data)
Parameter data
+ 2
+ 4
+ 6
+ 8
+ 10
Top address
+ 2
+ 4
+ 6
+ 8
+ 10
(Function)
18
(Completion)
?
(Data length)
L
(Number)
N
(Attribute)
M
[Input data structure] [Output data structure]
(Attribute)
M
(Data)
D
[Data length]
L = 1 : Reads bit or byte type parameter or pitch error compensation
value.
2 : Reads word type parameter.
4 : Reads 2 words type parameter.
When the servo parameter all axis is specified
L = 18 : Writes bit or byte type parameter.
28 : Writes word type parameter.
48 : Writes 2 words type parameter.
[Data number]
When the pitch error compensation value
N = 11000 to 11511 : Pitch error compensation value of the 1
st
(X) axis
E.4
WRITING THE
PARAMETER
(:LOW–SPEED
RESPONSE)