B–61863E/15
5. EDITING OF SEQUENCE
PROGRAM (EDIT)
PMC PROGRAMMER (CRT/MDI)
535
FUNCTN
When a wrong functional
instruction is entered or
[FUNCTN] key only is
pressed;
Functional
instruction table
[NEXT] key (to display the subsequent
functional instruction table)
Functional instruction generation soft key
(Press this key again when resetting the functional instruction
table to the original ladder diagram)
NOTE
If the system is left undone without inputting any data after
pressing soft key [FUNCTN], the other soft keys are not
employ–able. In such a case, press [FUNCTN] key again.
DECB
SUB 25
Ę
Format
specifi-
cation
ĘĘĘĘ
Code
data
address
ĘĘĘĘ
ĘĘĘĘ
Specifi–
cation
number
ĘĘĘĘ
Output
data
address
DECB
SUB 25
Ę
ĘĘĘĘ
ĘĘĘĘ
ĘĘĘĘ
ĘĘĘĘ
Input functional instruction parameters in the vertical direction
as shown in the following figure when inputting functional
instructions from CRT/MDI panel.
Format specification
Code data address
Specification number
Output data address
ACT
CRT/MDI
1 Input a control condition.
Press soft key [
], input the address and bit data, and
then, press <INPUT> key. The cursor shifts rightward.
2 Input an instruction.
Press soft key [FUNCTN], input SUB number 25, and then,
press <INPUT> key. A functional instruction diagram
appears as shown in the above figure.
3 Input an instruction parameter.
Input the first parameter, format specification, and then, press
<INPUT> key. The cursor automatically lowers downward.
Input three residual parameters in order.