3. LADDER DIAGRAM
MONITOR (PMC–SB7)
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
864
3
LADDER DIAGRAM MONITOR (PMC–SB7)
Pressing soft key [PMCLAD] displays the sequence program
dynamically. On the screen, you can monitor the LADDER Program
works.
The LADDER Diagram Editor screen allows you changing the LADDER
Diagram, adding relays and functional instructions, and changing the
action of LADDER Diagram.
LADDER Diagram Monitor/Editor function consists of following
screens.
a) LADDER Diagram Monitor screen
Displays LADDER Diagram and the current status of relays and
others.
b) Collective Monitor screen
Displays only selected ladder diagram and the current status of relays
and others.
c) LADDER Diagram Editor screen
Edits LADDER Diagram by the net.
d) Net Editor screen
Edits the structure of a net in LADDER Diagram
e) PMC Functional Instruction Data Table Viewer screen
Refers the contents of a data table of functional instruction.
f) PMC Functional Instruction Data Table Editor screen
Edits the contents of a data table of functional instruction.
g) Program List Viewer screen
Chooses the subprogram to be displayed at LADDER Diagram
Monitor screen.
h) Program List Editor screen
Edits LADDER Diagram by the subprogram. Also chooses the
subprogram to be displayed at LADDER Diagram Editor screen.
i) Step Sequence Monitor screen
Displays Step Sequence Diagram and the current status of step,
transition and others.
j) Subprogram List Viewer screen
Chooses the subprogram to be used at step sequence.
NOTE
You can hide [PMCLAD] soft key at PMC Main Menu by
setting the keep relay of K900.0 to 1.