B–61863E/15
1. SEQUENCE PROGRAM
CREATING PROCEDURE
PMC SEQUENCE PROGRAM
7
Table 1.1 PMC specifications (2)
Type of PMC
Specification
of PMC
PMC–SA1 PMC–SA2 PMC–SA3
Program method language Ladder Ladder Ladder
Number of ladder level 2 2 2
1st level execution period 8 ms 8 ms 8 ms
Mean processing time of basic
command
5.0
(µs/ step)
1.5
(µs/ step)
0. 15
(µs/ step)
*
Program capacity
D Ladder (step) (Note 1,3)
D Symbol, Comment
(Note 2,3)
D Message (Note 3)
D Language only
Approx. 3, 000
Approx. 5, 000
1 to 128KB
0. 1 to 64KB
–
Approx. 3, 000
Approx. 5, 000
Approx. 8, 000
Approx.12, 000
1 to 128KB
0. 1 to 64KB
–
Approx. 3, 000
Approx. 5, 000
Approx. 8, 000
Approx.12, 000
1 to 128KB
0. 1 to 64KB
–
Command Basic command
Function command
12 kinds
49 kinds
12 kinds
48 kinds
14 kinds
66 kinds
Internal relay (R)
Message request (A)
Keepmemory
D Variable timer (T)
D Counter (C)
D Keep relay (K)
D Data table (D)
Subprogram (P)
Label (L)
Fixed timer
1100 byte
25 byte
80 byte
80 byte
20 byte
1860 byte
–
–
Timer No. 100
devices specified
1118 byte
25 byte
80 byte
80 byte
20 byte
1860 byte
–
–
Timer No. 100
devices specified
1118 byte
25 byte
80 byte
80 byte
20 byte
1860 byte
512 programs
9999 labels
Timer No. 100
devices specified
I/O
D I/O link (I)
(O)
D I/O card (I)
(O)
1024 points max.
1024 points max.
156 points max.
120 points max.
1024 points max.
1024 points max.
156 points max.
120 points max.
1024 points max.
1024 points max.
156 points max.
120 points max.
Sequence program EPROM
1Mbit×1 (128KB)
(Note 4)
EPROM
1Mbit×1 (128KB)
EPROM
1Mbit×1 (128KB)
(Note 4)
NOTE
1 This is the number of ladder steps for the program only with basic instructions. The use of
functional instructions may vary the number of ladder steps.
2 The size of a symbol and that of a comment are fixed to 32KB.
The size of a message is fixed to 2.1KB.
The maximum size of a symbol and that of a comment are 64KB each.
3 These have no limit of size for each. However, the total size of sequence program (the sum total
of ladder, symbols/comments, messages, etc.) never exceed the storage size of sequence
program. The size of them influences the capacity of others.
4 FLASH ROM is used in the FANUC Series 20.
5 As values indicated with an asterisk (*) in the table, former versions of the programming manual
and catalogs have listed the mean processing time of basic commands, but this manual lists
the execution time for one step. The actual ladder program execution performance (speed) of
each PMC has not been changed.
6 Application PMC for FANUC Series 16–MODEL A loader control function is PMC–SA1.