B–61863E/15
2. SETTING FUNCTION
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
845
D DATA TBL CNTL SCREEN(PMC–SB7:K900.7, PMC–SA1:K17.7)
YES (0): Displays PMC parameter data table control screen.
NO (1): Does not displays PMC parameter data table control screen.
D HIDE PMC PARAM (PMC–SB7:K902.6, PMC–SA1:K19.6)
NO (0): Allows PMC parameter display and output.
YES (1): Prevents PMC parameter display and output.
NOTE
This setting effects some PMC functions.
Please refer to ”2.6 Programmer protection function.”
D PROTECT PMC PARAM (PMC–SB7:K902.7, PMC–SA1:K19.7)
NO (0): Allows PMC parameter change and read.
YES (1): Prevents PMC parameter change and read.
NOTE
This setting effects some PMC functions.
Please refer to ”2.6 Programmer protection function.”
D HIDE PMC PROGRAM(PMC–SB7:K900.0, PMC–SA1:K17.0)
NO (0): Allows sequence program display.
YES (1): Prevents sequence program display.
NOTE
This setting effects some PMC functions.
Please refer to ”2.6 Programmer protection function.”
D IO GROUP SELECTION (PMC–SB7:K906.1)
HIDE (0) : The selectable I/O link assignment function screen is
not displayed.
SHOW (1) : The selectable I/O link assignment function screen is
displayed.
D LADDER START(PMC–SB7:K900.2, PMC–SA1:K17.2)
AUTO (0): Executes the sequence program automatically after
the power turns on.
MANUAL(1): Executes the sequence program by [RUN] soft–key.
D ALLOW PMC STOP(PMC–SB7:K902.2, PMC–SA1:K19.2)
NO (0): Prevents run/stop operation of the sequence program.
YES (1): Allows run/stop operation of the sequence program.
NOTE
This setting effects some PMC functions.
Please refer to ”2.6 Programmer protection function.”