B–61863E/15
5. FUNCTIONAL INSTRUCTIONSPMC SEQUENCE PROGRAM
205
ACT=0 : Move instruction not executed.
ACT=1 : Executed.
If a code signal and another signal co–exist at address X35 for an input
signal from the machine tool, to compare the code signal and a code signal
at another address, the rest of signals in address X35 becomes an obstacle.
Thus, the MOVE instruction can be used to output only the code signal
at address X35 address R210.
MOVE
(SUB 8)
A
R228.1
(1)
0001
(2)
1111
(3)
X035
(4)
R210
7654 321 0
Address X35
Code signal
Another signa
0 0 0 1 1 1 1 1
Logical multiplication data
Low–order four–bit logical multiplication data
High–order four–bit logical multiplication data
0 0 0
Address R210
Code signal
Fig. 5.16.4 MOVE instruction ladder diagram
5.16.3
Execution Command
5.16.4
Example of Using the
MOVE Instruction