4. PMC DATA SETTING AND
DISPLAY (PMCPRM)
B–61863E/15
PMC–NB6 MANIPULATION
690
NOTE
The meanings of the table parameters are as follows:
#7 #6 #5 #4 #3 #2 #1 #0
0: Binary format
1: BCD format
0: Input protection disabled
1: Input protection enabled
0: Binary or BCD format (with bit 0 valid)
1: Hexadecimal format (with bit 0 invalid)
(2)Data table screen
If the data table control data is specified, clicking the [G.DATA] soft
key on the data table control data screen displays the data table setting
screen.
Table contents
D NO.
D ADDRESS: Address used by the sequence program
D DATA
Soft key definitions
[C.DATA]: Clicking this soft key switches to the data table control
data screen.
[G–SRCH]: After the entry of a group number for a data table to be
searched in another group, clicking this key moves the
cursor to the beginning of that group.
[SEARCH]: After the entry of an address, clicking this key moves the
cursor to the specified address within the currently
selected group. When entering the address, the “D” can
be omitted from the beginning of the address. After
entering “101” for example, clicking this key moves the
cursor to data using D101.