B–61863E/15
C. WINDOW FUNCTION DESCRIPTION
(PMC–NB/NB2/NB6)
APPENDIX
1443
[Description]
Feedrate writing can be specified only in the feed–per–minute mode. The
velocity command is specified with F 10
–d
. A flag is provided to
validate either the command of the PMC or the feedrate of the CNC. After
the flag is set, the velocity command specified in the NC is invalidated.
To validate the feedrate of the NC, set the flag to 0.
0
Function code
216
Completion code
Data length
6
Data number
0
Data attribute
0
Feedrate
(6 byte)
2
4
6
8
10
Set data
16
DATA+0
DATA+2
DATA+4
DATA+6
Feedrate, F
Exponent
of feedrate, d
(Note 1) Format of feedrate
7 6 5 4 3 2 1 0
Flag for validating the velocity command
: Bit 2 of DATA+0
(0: The NC is valid.
1: The PMC is valid.)
Feedrate, F : DATA+2 and DATA+3
Exponent of feedrate, d : DATA+4 and DATA+5
NOTE
With the FS15i–A (PMC–NB6), this function is of the
low–speed type. Therefore, this function need not be
interlocked with other windows.
C.4.19
Writing the Feedrate