3. ADDRESS
B–61863E/15
PMC SEQUENCE PROGRAM
64
Table 3 Alphabetic characters in address numbers (3)
Chara–
Model
cter
Signal description
PMC-SB PMC-SB2 PMC-SB3 PMC-SC PMC-SC3 PMC-NB
X Signal from the machine to the
PMC (MT to PMC)
X0 to X127
X1000 to X1039
X0 to X127
Y Signal from the PMC to the
machine (PMC to MT)
Y0 to Y127
Y1000 to Y1029
Y0 to Y127
F Signal from the NC to the PMC
(NC to PMC)
F0 to F255
F1000 to F1255
F0 to F319
G Signal from the PMC to the NC
(PMC to NC)
G0 to G255
G1000 to G1255
G0 to G511
R Internal relay (Caution 1) R0 to R999
R9000 to
R9099
R0 to R999
R9000 to
R9117
R0 to R1499
R9000 to
R9117
R0 to R1499
R9000 to
R9099
R0 to R1499
R9000 to
R9117
R0 to R1499
R9000 to
R9117
A Message request signal A0 to A24
C Counter C0 to C79
K Keep relay (Caution 2) K0 to K19
D Data table D0 to D1859 D0 to D2999
T Variable timer T0 to T79
L Label number – – L1 to L9999 – L1 to L9999
P Subprogram number – – P1 to P512 – P1 to P512
CAUTION
1 R9000 to R9117 are areas reserved for the PMC system
program; these areas cannot be used for output by a
sequence program.
2 K17 to K19 are areas reserved for the PMC system
program; these areas cannot be used for output by a
sequence program.