7. WRITING, READING, AND VERIFYING
THE SEQUENCE PROGRAM AND
PMC PARAMETER DATA
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
572
(b) Setting the transfer conditions
Press the [SPEED] soft key and set each condition. See Subsection
7.3.6 for details.
(c) Writing a file
Item Operation
DEVICE Press the [FDCAS] soft key.
FUNCTION Press the [WRITE] soft key.
DATA KIND Select the type of data to be output (see (3) in Section 7.2).
FILE NO. Name the file within 17 characters. –1 is displayed if no name is entered
(see (5) in Section 7.2).
Press the [EXEC] soft key to start outputting the file.
(d) Reading a file
Item Operation
DEVICE Press the [FDCAS] soft key.
FUNCTION Press the [READ] soft key.
FILE NO. Enter the number or name of the file to be input.
Press the [EXEC] soft key to start inputting the file.
(e) Collating a file
Item Operation
DEVICE Press the [FDCAS] soft key.
FUNCTION Press the [COMPAR] soft key.
FILE NO. Enter the number or name of the file to be collated.
Press the [EXEC] soft key to start collating the file.
Note
PMC data cannot be collated. The data the file is to be
collated with depends on the file.
(f) Deleting a file
Item Operation
DEVICE Press the [FDCAS] soft key.
FUNCTION Press the [DELETE] soft key.
FILE NO. Enter the number or name of the file to be deleted.
Press the [EXEC] soft key to start deleting the file.
(g) Listing the files
Item Operation
DEVICE Press the [FDCAS] soft key.
FUNCTION Press the [LIST] soft key.
Press the [EXEC] soft key to start listing the files.