11. PMC PROGRAMMER (DPL/MDI)
(ONLY FOR THE Power Mate)
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
624
Selecting SYSTEM PARAM on the PMC programmer menu displays the
system parameter screen. If the sequence program is running, selecting
this function automatically stops the program.
1 Display the PMC programmer menu.
2 Display the SYSTEM PARAM item by pressing the <↓> or <↑> key.
PMC PRG MENU 3/3
>SYSTEM PARAM
3 Press the <INPUT> or <READ> key. The system parameter screen
appears.
CTR TYPE = BIN
(BINARY=0/BCD=1)
4 The current counter data type is displayed on the screen.
(a) Specify the type of the counter value to be used for the CTR
functional instruction, as binary or BCD (enter <0> for binary or
<1> for BCD).
(b) Press the <INPUT> key.
The counter data type is set.
5 Pressing the <CAN> or <WRITE> key displays the PMC
programmer menu.
CAUTION
If the PMC parameter keep relay K19#0 is set to 1, the
screen for writing a sequence program into FLASH ROM is
displayed upon the completion of editing. (This is applicable
to the Power Mate–H and Power Mate i–D/H only).
Write a sequence program into FLASH ROM as explained
in Section 11.7.
DEVICE=F–ROM
>WRITE Y/N [YES]
11.2
SETTING AND
DISPLAYING SYSTEM
PARAMETERS
(SYSTEM PARAM)