3. LADDER DIAGRAM
MONITOR (PMC–SB7)
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
870
When cursor is hidden, the net that has the specified net number
or contains the specified address will be shown at the top of the
screen.
When cursor is shown, the cursor moves to the relay or the
parameter to show the found address directly.
D [W–SRCH] Search Write Coil
Searches for the write coils with the address that entered string
means. Any contacts with the address are ignored.
D [F–SRCH] Search Functional Instruction
Searches for the functional instructions by its SUB number or
its mnemonic name such as ”TMR” or ”END2”.
D [PICKUP] Taking of ladder net into collective monitor screen
The ladder net which executes the monitor is taken into the
collective monitor screen.
D [PREV] Search previous
Repeats to search the same thing backward (upward).
D [NEXT] Search next
Repeats to search the same thing forward (downward).
D [GLOBAL] / [LOCAL] Change range for searching
Changes the range for searching between GLOBAL and LOCAL;
GOBAL means whole of program, and LOCAL means within the
displaying subprogram. Current range for searching is indicated
at right of the information line at top of screen.
3 [TABLE] Go to Functional Instruction Data Table Viewer screen
Goes to Functional Instruction Data Table Viewer screen to
examine contents of Data Table of functional instructions such as
COD (SUB 7) and CODB (SUB 27), which have Data Table in
themselves. This soft key appears only when the cursor is on a
functional instruction that has Data Table.
4 [EDIT] Go to LADDER Diagram Editor screen
Goes to LADDER Diagram Editor screen. This soft key appears
only when Programmer function
1
is enabled. And activating
Online Monitor function
2
disables this soft key.
NOTE
1 To enable Programmer function, go to GENERAL screen of
PMC Settings, and choose ”YES” at item ”PROGRAMMER
ENABLE”.
2 To deactivate Online Monitor function, go to ONLIEN screen
of PMC Settings, and choose ”NOT USE” at settings of
”RS–232C” and ”F–BUS” (if appears).
5 [SWITCH] Calling collective monitor screen
The screen display is switched into the Collective Monitor screen.
6 [SETING] Screen settings
Goes to setting screen for LADDER Diagram Monitor screen. You
can change various settings for LADDER Diagram Monitor screen
at the screen. Use Return key [<] to return to LADDER Diagram
Monitor screen. See ”Settings for LADDER Diagram Monitor”
section for the detail.