11. PMC PROGRAMMER (DPL/MDI)
(ONLY FOR THE Power Mate)
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
626
When ladder mnemonic editing (LADDER) is selected from the PMC
edit menu, the ladder mnemonic edit screen is displayed.
When this function is selected, the sequence program stops.
1 Display the PMC edit menu screen.
2 Display the LADDER item by pressing the <±> or <°> key.
PMC EDIT 1/1
>LADDER
3 Press the <INPUT> or <READ> key.
When a password is set for the ladder: Proceed to step 4.
When no password is set for the ladder: Proceed to step 6.
4 If a password is set, a password clear request is displayed.
PASSWORD (R/W)
NOTE
For a ladder for which a password has been set, the ladder
mnemonic editing function cannot be started unless the
correct password is entered. Once the password is cleared,
the password remains cleared until the power is turned off
then back on.
5 Enter the password, then press the <INPUT> key.
NOTE
The entered password is not displayed (not echoed back on
the screen).
If the entered password is incorrect, the following error message is
displayed.
FALSE PASSWORD
If the <INPUT> key is pressed at this time, the screen display returns
to the password clear request screen.
If the <CAN> key is pressed at this time, the screen display returns
to the PMC edit menu.
If the entered password is correct, the password is cleared.
11.4
EDITING LADDER
MNEMONICS
11.4.1
Starting Ladder
Mnemonics Editing