B–61863E/15
3. ADDRESS
PMC SEQUENCE PROGRAM
91
D Related hardware publications:
FANUC I/O Unit–MODEL B Connection and Maintenance Manual
(B–62163E)
I/O Unit MODEL Bs can be used together with a Power Mate operator
panel interface unit, connection unit, and I/O Unit MODEL As.
In this case, the I/O Unit MODEL Bs occupy one group; that is, no other
type of unit can be present in that group.
An example of connection is shown below.
[GROUP] =0
[GROUP] =1
[GROUP] =2
[GROUP] =3
I/O unit model B
interface unit
I/O unit model B
DI/DO unit
(Unit No.=1)
I/O unit model B
DI/DO unit
(Unit No.=20)
I/O unit model B
DI/DO unit
(Unit No.=5)
I/O unit model B
DI/DO unit
(Unit No.=10)
I/O unit model B
DI/DO unit
(Unit No.=30)
I/O unit model B
DI/DO unit
(Unit No.=9)
I/ O LINK
MASTER
Power Mate
[BASE] =0, [SLOT] =1
Operator’s panel
interface unit
[BASE] =0, [SLOT] =1
[BASE] =0 [BASE] =1
[BASE] =0, [SLOT] =1 [BASE] =0, [SLOT] =20
[BASE] =0, [SLOT] =5 [BASE] =0, [SLOT] =10
→SLOT No. →SLOT No.
I/O Unit– A I/O Unit– A
[BASE] =0, [SLOT] =30 [BASE] =0, [SLOT] =9
3.2.4
I/O Unit MODEL B
Assignment