11. PMC PROGRAMMER (DPL/MDI)
(ONLY FOR THE Power Mate)
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
636
The on–line debugging function enables the monitoring and modification
of ladder programs and signal status on personal computer’s screen using
a personal computer connected to the Power Mate through an RS–232C
cable.
CAUTION
The additional option of the Ladder On–line debugging
function is necessary to use the on–line debugging function
on PMC–PA3 for Power Mate–D.
FANUC FANUC LADDER–II is necessary to use the on–line debugging
function. (This software is a programming system for developing
FANUC PMC sequence programs which operate on IBM PC/AT and
compatible computers.)
Software name Specification Personal computer
FANUC LADDER–II A08B–9201–J503 IBM PC/AT and compatible
In this section, only the parameter of on–line monitor driver for Power
Mate–H and attention in use is described. Other points(connection of
cable with personal computer, details of the operation, etc.) are described
in the following manual.
Name of Manual Spec.No. Reference Items
FANUC LADDER–II OPERATOR’S MANUAL B–66184EN On–line function
When using the on–line debugging function to connect a personal
computer to the PMC, first start the driver that provides the
communication function of the PMC.
When starting or stopping the driver, it is necessary to set either of the
following parameters.
D Parameter screen for on–line monitor(dPARAMETERS FOR ONLINE
MONITORc)
Pressing the [MONIT] then [ONLINE] soft keys on the PMC menu
screen causes the on–line monitor parameter screen to appear.
ParameterdRS–232Cc = dUSEc : On–line monitor driver is used.
dNOT USEc: On–line monitor driver is not
used.
CAUTION
The CRT/MDI is necessary when the parameter is set on the
“PARAMETERS FOR ONLINE MONITOR” screen.
11.10
ON–LINE
DEBUGGING
FUNCTION
(ONLY FOR Power
Mate–D/H AND Power
Mate i–D/H)
11.10.1
Starting and Stopping
the On–line Debugging
Function