1. SEQUENCE PROGRAM
CREATING PROCEDURE
B–61863E/15
PMC SEQUENCE PROGRAM
28
Table 1.1 PMC specifications (15)
Series 0i–B Series 0i Mate–A/B
Model
PMC–SA1 PMC–SB7 PMC–SA1
Programming method Ladder Ladder Ladder
Number of ladder levels 2 3 2
First–level execution period 8 ms 8 ms 8 ms
Basic instruction processing time 5.0 µ sec/step 0.033 µ sec/step 5.0 µ sec/step
Program capacity
S Ladder(step) (Note 1,2)
S Symbol & Comment (Note 2)
S Message (Note 2)
About 5,000
1 to 128KB
0.1 to 64KB
About 24,000
1KB or more
8KB or more
About 5,000
1 to 128KB
0.1KB to 64KB
Basic instructions
Functional instructions
12
48
14
69
12
48
Internal relay (R)
Extra relay (E)
Message request (A)
Nonvolatile memory
S Data tables (D)
S Variable timers (T)
Fixed timers
S Counters (C)
Fixed counters (C)
S Keep relays (K)
Subprograms (P)
Labels (L)
1,100 byte
–
200 points (25 byte)
1,860 byte
40 points (80 byte)
100 points
20 points (80 byte)
–
20 byte
–
–
8,500 byte
8,000 byte
2,000 points (500 byte, 2 bit/point)
10,000 byte
250 points (1,000 byte, 4 byte/point)
500 points (Timer number specify)
100 points (400 byte, 4 byte/point)
100 points (200 byte, 2 byte/point)
120 byte
2000
9999
1,100 byte
–
200 points (25 byte)
1,860 byte
40 points (80 byte)
100 points
20 points (80 byte)
–
20 byte
–
–
Machine interface
(I) Max.
(O) Max.
Machine operator’s panel
1,024 points Max. (Note 3)
1,024 points Max. (Note 3)
available
1,024 points Max. (Note 3)
1,024 points Max. (Note 3)
available
96 points Max. (Note 4)
64 points Max. (Note 4)
available
Sequence program storage Flash ROM
128KB
Flash ROM
128KB
256KB
Flash ROM
128KB
NOTE
1 This is the number of ladder steps for the program only with basic instructions. The use of
functional instructions may vary the number of ladder steps.
2 These have no limit of size for each. However, the total size of sequence program (the sum total
of ladder, symbols/comments, messages, etc.) never exceed the storage size of sequence
program. The size of them influences the capacity of others.
3 Maximum points of machine interface contain the point of Built–in I/O. Built–in I/O has DI 96
points, DO 64 points and it uses group 0 of I/O Link.
4 Only Distribution I/O Operator’s Panel I/O Modules(Input 48points / Output 32points) can be
connected. Two Distribution I/O Operator’s Panel I/O Modules is available.