1. SCREEN OPERATION
FOR FS16i/18i/21i/0i–B
PMC–SA1/SB7
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
838
For the PMC–SA1, the operability and function have been improved as
follows, as compared with the Series 21i–A PMC and the Series
16i/18i/21i–A loader control PMC–SA1.
D Edit functions which is embedded in PMC control software
D Reinforcement of programmer protection function
When pressing soft–key [PMC] in CNC system menu screen, PMC main
menu appears. The following is the summary of PMC screen tree. The
hatched part below indicates the screen that was changed in the Series
16i/18i/21i/0i–B PMC SA1. The other screens are the same as those of
the PMC–SA1. See ”II. PMC Operation (CRT/MDI)” and ”III. PMC
Programmer”.
[PMC] [PMCLAD] LADDER DIAGRAM MONITOR
[PMCDGN] [TITLE] TITLE DATA
[STATUS] SIGNAL STATUS
[ALARM] ALARM
[TRACE] SIGNAL TRACE
[IOCHK] I/O LINK CONNECTING CHECK
[PMCPRM] [TIMER] TIMER
[COUNTR] COUNTER
[KEEPRL] KEEP RELAY
[DATA] [G.DATA] DATA TABLE
[SETING] SETTING
[RUN]/[STOP] START AND STOP OF SEQUENCE PROGRAM
[EDIT] [TITLE] TITLE DATA EDITOR
[LADDER] LADDER DIAGRAM EDITOR
[SYMBOL] SYMBOL DATA EDITOR
[MESAGE] MESSAGE DATA EDITOR
[MODULE] I/O UNIT ADDRESS SETTING
[CROSS] CROSS REFERENCE
[CLEAR] CLEARING SEQUENCE PROGRAM
[I/O] INPUT AND OUTPUT OF SEQUENCE
PROGRAM AND PMC PARAMETER
[SYSPRM] SYSTEM PARAMETER
[MONIT] [ONLINE] ONLINE SETTING
The following system keep relays are added.
Item Meaning PMC–SA1
EDIT ENABLE Allows editing the ladder program. K18.6
ALLOW PMC STOP Allows start /stop of ladder program. K19.2
Please refer to ”5. SETTING FUNCTION” for detail.
1.1
SCREEN OPERATION
FOR PMC–SA1
1.1.1
Structure of Software
Key in PMC
1.1.2
Addition of System
Keep Relays