B–61863E/15
L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
APPENDIX
1531
Model
PMC address type
Power Mate–D Power Mate–D/H Power Mate i–D/H
PMC–PA1 PMC–PA3 PMC–SB5 PMC–SB6
Inner relay (R) R0 to R999
R9000 to R9099
R0 to R999
R9000 to R9117
R0 to R1499
R9000 to R9117
R0 to R2999
R9000 to R9199
Message request signal (A) A0 to A24 A0 to A124
Variable timer (T) T0 to T79 T0 to T299
Counter (C) C0 to C79 C0 to C199
Keep relay (K) K0 to K19 K0 to K39, K900 to K909
Data table (D) D0 to D1859 D0 to D2999 D0 to D7999
Subprogram number (P) – P1 to P512 P1 to P2000
(5)Function command specification expansion
Expanded specifications have been added to the function commands
DECB, NUMEB, XMOVB, and PSGN2. The conventional, basic
specifications are still valid and, therefore, sequence programs need
not be changed for migration. For an explanation of the expanded
specifications, see Section I.5, “PMC Function Commands.”
(6)Changes in a window function
The CNC alarm state read function code has been changed from 23 to
186. In addition, the window function has been changed to the
low–speed type. For details, see Section B.4.83.