B–61863E/15
5. FUNCTIONAL INSTRUCTIONS
PMC SEQUENCE PROGRAM
289
(iii) Example
To input ATC?
OK when characters A, T, C, O, and K are
registered in the CRT/MDI unit, enter the following:
4434 3A3A
01
NOTE
1 To define @, enter @40...@, where 40 is the code
corresponding to @40
. . . . . @
Code for @
2 To renew the message line displayed on the CRT/MDI
screen, input as:@ OA @ at the end of the data.
3 When using numerical codes, @ code occupies 1 byte, and
space code occupies 2 bytes. (Space code = 20, 2 and 0
occupies 1 byte each).
4 The following control codes are used: 02: 2–byte code (kanji
and hiragana characters) 01: 1–byte code (alphanumeric
and half–width kana characters) Do not specify 02 or 01
between @02 and 01@, as follows. The characters may not
be correctly displayed. @02 ... 02 ... 01@ @02 ... 01 ...
01@
5 Spaces are used between each numerical code in example
to understand easily, but do not use them actually.
Table 5.44.6 Character code table
2 3 4 5 A B C D
0 (Space) 0 @ P ~ _ *3)
1 ! 1 A Q
2 # 2 B R
3 # 3 C S
4 $ 4 D T
5 % 5 E U
6 & 6 F V
7 ’ 7 G W
8 ( 8 H X
9 ) 9 I Y
A * : J Z
B + ; K [
C , < L ¥
D − *1) = M ]
E · > N ƞ
F / ? O __ *2)
*1) Minus, *2) Under bar, *3) Long bar *4) Dakuten *5) Han–dakuten