B–61863E/15
B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
APPENDIX
1165
[Completion codes]
0 : Setting data has been written normally.
2 : The byte length of the setting data specified for writing is invalid.
3 : The setting data number specified for writing is invalid.
4 : The specified data attribute is invalid because it is neither 0, –1,
nor a value from 1 to n (n is the number of axes).
5 : Data exceeding the allowable range was specified as setting data
to be written. For example, when data outside the range from 0
to 3 is specified as the setting data to be written for I/O data, this
completion code is returned.
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
20
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(N = Input data)
(Data number)
N
(N = Input data)
(Data attribute)
M
(M = Input data)
Setting data: Input data Setting data–dependent form
Value