D. WINDOW FUNCTION DESCRIPTION
(FS16/16i–LA/16i–LB)
B–61863E/15
APPENDIX
1452
(2) Transfer from non–volatile memory to data area (% low–speed type)
[Contents of data]
The data can be transferred from the processing condition file registered
in non–volatile memory to the data area in CNC by PMC–SC application.
Setting the forward data set or group in data attribute M.
Setting the original read address for the offset address from non–volatile
memory top address in address N.
Setting the total byte No. of original data set in address L.
Setting the original structure of set in data.
And the data of set or group can be transferred from non–volatile memory
to data area.
[Structure of input data]
Top address + 0
2
4
6
8
10
(Function code)
184
(End Code)
—
(No need to set)
(Data length)
L
(Group No.)
N
(Data attribute)
M
(Data)
L = Set the total byte No. of the data structure
for 1 set in non–volatile memory.
This data must be set in case of transferring
the data group.
(No–need to set in case of transferring the set)
The following End Code is output at reading end.
0 : normal end
3 : The incorrect data is set in Address.
4 : The incorrect data is set in Data attribute.
N = Set the original address by the offset from
the top address of non–volatile memory.
M = Set the kind of data set or group to transfer
1–10 : Set of processing data
101–103 : Set of piercing d data
201–205 : Set of edge process data
1000 : Group of processing data
1001 : Group of piercing data
1002 : Group of edge process data
Set the correspondence of 1 set of data item in
data area and data item in non–volatile memory
by relative address for non–volatile memory.
(See note for details.)
Structure of data set