6. LADDER DIAGRAM MONITOR
AND EDITOR
B–61863E/15
PMC–NB6 MANIPULATION
716
ACTIVE RELAY COLOR
ACTIVE RELAY BACKGROUND
Color setting for the active relay. When a contact allows power
flow, and when a coil receives power, they are active and are
displayed with this color setting. When contacts and coils are not
active, they are displayed with ”general color”. You can specify
these colors in the same manner as color setting of DIAGRAM
COLOR and DIAGRAM BACKGROUND.
PARAMETER COLOR
PARAMETER BACKGROUND
Color setting for the monitor of functional instruction
parameters. They are displayed when functional instructions are
displayed in the shape other than ”COMPACT”. You can specify
these colors in the same manner as color setting of DIAGRAM
COLOR and DIAGRAM BACKGROUND.
COMMENT COLOR
COMMENT BACKGROUND
Colors for the relay comment are set. You can specify these
colors by entering color number, or by moving right and left
cursor. 16 colors (from No.0 to No.15) are available. Foreground
color should be different from background one.
(b) Soft keys
LADDER Diagram Monitor Setting screen has the soft keys of options
and following:
D [INIT] Initialize all settings
All settings will be initialized to the default values.