#2 TRGSTAT 0 : The trigger stop function does not automatically start at power on.
1 : The trigger stop function starts automatically at power on.
#1 DBGSTAT 0 : The automatic break processing of C language debug function does
not start at power on.
1 : The automatic break processing of C language debug function start at
power on.
: This flag is effective when PMC C program is used.
#0 IGNKEY 0 : Function keys are enabled for a user program on the PMCMDI screen.
1 : Function keys are disabled for a user program on the PMCMDI
screen.
: This flag is effective when PMC C program is used. When this flag is
set to 1, the PMCMDI screen cannot be switched to the CNC screen
by using function keys. Program which invariably sets this flag to 0,
or which switches the PMCMDI screen to the NC screen, must be
prepared.
#7
PTCTPRMK19
or
K902
#6
HIDEPRM
#5 #4 #3 #2
ALWSTP
#1
C–REJECT
#0
FROM–WRT
#7 PTCTPRM 0 : Modification of PMC parameters and input PMC parameters from the
outside are enabled.
1 : Modification of PMC parameters and input PMC parameters from the
outside are disabled.
#6 HIDEPRM 0 : The display of PMC parameters and the output of PMC parameters to
the outside are enabled.
1 : The display of PMC parameters and the output of PMC parameters to
the outside are disabled.
#2 ALWSTP 0 : The execution/stop operation of a sequence program is disabled.
1 : The execution/stop operation of a sequence program is enabled.
#1 C–REJECT 0 : The system activates PMC C program.
1 : The system does not activate PMC C program.
#0 FROM–WRT 0 : Sequence program is not automatically written to F–ROM after
editing.
1 : Sequence program is automatically written to F–ROM after editing.
#7
K906
#6 #5
TRCSTAT
#4
MSHIFTKENBL
#3
NOEOUTPUT
#2
IOCHK
#1
IOSELSCN
#0
OVRRIDE
#5 TRCSTAT 0 : Starts trace function when the execution soft key is pressed.
1 : Starts trace function automaticcaly at power on.
: This flag is effective on PMC–SB7.
#4 MSHIFTKENBL 0 : Setting a multi–language alarm/operator message display function in
keep relay is disabled.
1 : Setting a multi–language alarm/operator message display function in
keep relay is enabled.
: This flag is effective on PMC–SB7.