5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
164
(5) W1
The operation results of a functional instruction, when represented with
one bit of 1 or 0, is output to W1 whose address can be determined freely
by the programmer. Its meaning varies with each functional instruction.
Note that some functional instructions have no W1.
(6) Data to be processed
Data handled by functional instructions are of binary coded decimal
(BCD) code and binary code.
In the conventional PMCs, the numeric data is processed mainly
based on the BCD code. However, in the PMC–SB/SC, it is
recommended to handle all pieces of numeric data with the binary
code. The reasons for this are:
(a) In the Series 16, the numeric data (M, S, T, B code) between the
CNC and the PMC should be of the binary code.
(b) Numeric data on which the CPU performs processing must be in
binary format. When numeric data is always processed in binary
format, therefore, neither BCD–to–binary nor binary–to–BCD
conversion is necessary, thus enabling faster PMC processing.
(c) When the data is of the binary code, the range of the numeric data
processable becomes wide. Also, negative numeric data can be
processed easily, and the arithmetic operation functions are
strengthened. The binary numeric data is handled, as a rule, on
the basis of 1 byte (–128 to+127), 2 bytes (–32768 to +32767),
and 4 bytes (–99999999 to +99999999).
(d) When various numeric data items are entered or displayed using
the keys on the CRT/MDI panel, all the numeric data items in
binary are conveniently specified or displayed in decimal
.
Therefore, no problem arises, though the data stored in the
internal memory is of the binary code. Pay attention to this only
when referring to the memory by the sequence program. See (7).
In the functional instructions, binary data is mainly handled.
(7) Example of numeric data
(a) BCD code data
The basic data handled with the BCD code is of 1 byte (0 to 99)
or 2 bytes (0 to 9999). The BCD 4–digit data is entered into two
bytes of continuous addresses as shown below.
Example: When BCD data 1234 is stored to addresses R250
and R251.
0 0 1 1 0 1
7654 32
0
1
0
0
3 4
R250
0 0 0 1 0 0
7654 32
1
1
0
0
1 2
R251
Specify smaller address R250 by a functional instruction.
(Note) The low order digits are entered to the smaller address.