4. SPECIFYING AND DISPLAYING
SYSTEM PARAMETERS
(SYSPRM)
B–61863E/15
PMC PROGRAMMER (CRT/MDI)
522
(b) LED DO ADDRESS
Specify a PMC address representing the first address of the external
DO actually connected (Y0 to Y127, Y200 to Y327, or Y1000 to
Y1014).
(c) KEY BIT IMAGE ADDRESS
Specify a PMC address representing the first address of the key
image to be referenced by the user program. Usually specify an
arbitrary internal relay (R) area.
(d) LED BIT IMAGE ADDRESS
Specify a PMC address representing the first address of the key
image to be generated by the user program. Usually specify an
arbitrary internal relay (R) area.
When creating new programs with the built–in editing function, set this
parameter first, then execute CLEAR ALL or perform clear operation
(turn on power while holding down X and O) at power on.
When selecting the step sequence method: STEP SEQUENCE = YES
When selecting the ladder method: STEP SEQUENCE = NO
When creating a new program for assignment of the I/O Link channel 2
with the built–in editing function, set this parameter first, then execute
CLEAR ALL or perform clear operation (turn on power while holding
down X and O) at power on.
When assigning the I/O Link channel 2
(Note1): I/O LINK 2 CHANNEL = YES
When assigning only the I/O Link channel 1
(Note2): I/O LINK 2 CHANNEL = NO
(8) STEP SEQUENCE
(9) I/O Link 2 CHANNEL
(PMC–SB6 for Series
16i/18i/21i/160i/180i/