B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
B–61863E/15
APPENDIX
1312
NOTE
The valid range of data number n is calculated as follows:
where,
1: Number of target axes 1
a= 2: Number of target axes 2
4: Number of target axes 3 and 4
b= 1: Sample data store function OFF
2: Sample data store function ON
The valid range of number of data items I is calculated as
follows:
1vlv20
0 v n v (524288
1
a
1
b
)–1
[Completion codes]
0 : The stored torque data (any data) was read successfully.
2 : Incorrect data length, that is, a value other than 6 is specified.
3 : Incorrect data number, that is, a value other than 11 to (10+n) (n:
number of spindles) is specified.
4 : The fine torque sensing data in ’Data Attribute’ has a wrong value,
that is, a value other than 0 or 1.
5 : Incorrect data area is specified. See Note for details of value
ranges.
6 : The fine torque sensing option has not been added on.