5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
196
This instruction is used to control rotating elements including the tool
post, ATC (Automatic Tool Changer), rotary table, etc. In the ROT
command (5.12) a parameter indicating the number of rotating element
indexing positions is a fixed data in programming. For ROTB, however,
you can specify an address for the number of rotating element index
positions, allowing change even after programming. The data handled are
all in the binary format. Otherwise, ROTB is coded in the same way as
ROT.
Fig.5.13.2 shows the expression format of ROTB
DIR
W1
POS
ROTB
(SUB 26)
INC
ACT
f
Format
specifi–
cation
RN0
*
ffff
Rotating
element
indexed
position
address
*
ffff
Current
position
address
*
ffff
Target
position
address
*
ffff
Arith–
metic
result
output
address
Fig. 5.13.2 Expression format of ROTB
The control conditions do not differ basically from those for ROT
command described in section 5.12. However, BYT has been eliminated
from ROTB (it forms part of the ROTB parameters).
For the reset, see ROT.
5.13
ROTB
(BINARY ROTATION
CONTROL)
5.13.1
Function
5.13.2
Format
5.13.3
Control Conditions