L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
B–61863E/15
APPENDIX
1540
This is the specification for the format to output the PMC nonvolatile
parameter to I/O device.
(1)Timer (T)
[Format]
N60xxx Pnnnnn; Setting value of timer
N: The numbers of timer address plus 60000.
The range:
PMC–SA1/SA5/SB5: N60000 to N60078
PMC–SB6: N60000 to N60298
P: The timer value with decimal numeric. The effective values
are from 0 to 32767.
(Example)
N60000 P1; Timer Number 1 T0
N60002 P20; Timer Number 2 T2
........
N60078 P32767; Timer Number 40 T78
(2)Counter (C)
[Format]
N61xxx Pnnnnn; Counter Reset Value, Counter Current Value
N: The numbers of counter address plus 61000.
The range:
PMC–SA1/SA5/SB5: N61000 to N61078
PMC–SB6: N61000 to N61198
P: The counter value with decimal numeric. The effective
values are from 0 to 32767. Counter Preset value and
Counter Current value are output alternately. Binary data are
always output regardless of the setting of BCD format or
binary format.
(Example)
N61000 P7; Counter Number 1 C0
N61002 P7; C2
.......
N61076 P9999; Counter Number 20 C76
N61078 P0; C78
(3)Keep relay (K)
[Format]
N62xxx Pnnnnnnnn;
N: The numbers of keep relay address plus 62000.
The range:
PMC–SA1/SA5/SB5: N62000 to N62019
PMC–SB6: N62000 to N62039, N62900 to
N62909
L.3.2
PMC Parameter Format
L.3.2.1
General
L.3.2.2
Format for PMC–MODEL
SA1/SA5/SB5/SB6