5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
272
(a) Message number:
The specified number produces an appropriate event as follows.
1000 to 1999 (alarm message):
The CNC is put in alarm status and the number and following data
are displayed. The maximum number of the displayed characters
is up to 32, except for the message number. When an alarm status
occurs, the operation being executed stops. To release the alarm
status, set the display–request bit (see Fig.5.43.7) to 0.
2000 to 2099 (operator message):
The CNC is not put in alarm status and the number and following
data are displayed. The maximum number of the displayed
characters is 255, except for the message number.
2100 to 2999 (operator message):
The CNC is not put in alarm status and the number is not displayed.
Only the following data (up to 255 characters) is displayed.
5000 to 5999 (alarm messages on path 2):
Path 2 is placed in the alarm state. A displayed message number is
a specified number from which 4000 is subtracted. The number of
displayed characters excluding this number is 32 or less. If the
alarm state arises during axis movement, a gradual stop occurs. The
alarm state can be released by setting the display request bit to 0.
7000 to 7999 (alarm messages on path 3):
Path 3 is placed in the alarm state. The displayed message number
is a specified number from which 6000 is subtracted. The number
of displayed characters excluding this number is 32 or less. If the
alarm state arises during axis movement, a gradual stop occurs. The
alarm state can be released by setting the display request bit to 0.
NOTE
If all characters in the operator message are kana
characters, up to 254 kana characters are displayed.
(b) Message character
An alphanumeric character is specified with a two–digit decimal
(two characters per step). Table 5.43.6 shows the correspondence
between characters and specified numbers.
The above message data is always specified because it is written on
ROM. The message data cannot therefore be changed as desired.
However, arbitrary numeric data of up to four BCD digits can be
displayed according to the specified variable data. The spindle tool
number which changes whenever ACT tools are changed and the
number of the tool at the tool–change position can be displayed, for
example. For specifying variable data, see 5.43.10 below.
5.43.5
Message Data