B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
B–61863E/15
APPENDIX
1244
[Output data structure]
Top address + 0
2
4
6
8
10
(Function code)
74
(Completion code)
?
(See the explanation of
the completion codes.)
(Data length)
L
(L = 4*n. n is the number of
specified axes.)
(Data number)
—
(Data attribute)
M
(M: Input data)
Relative coordinates on the specified
controlled axis (4 bytes)
Signed binary
(A negative value is represented in 2’s
complement.)
Value
10
14
Relative coordinates on the second
axis (4 bytes)
Signed binary
(A negative value is represented in 2’s
complement.)
Value
Relative coordinates on the first axis
(4 bytes)
18
Relative coordinates on the third axis
(4 bytes)
22
Relative coordinates on the fourth axis
(4 bytes)
When the number of controlled axes is 4
Output data unit
Input system Increment system IS–B Increment system IS–C
mm, deg system 0.001 0.0001
inch system 0.0001 0.00001
0.001 0.0001
mm, deg system
0.001 0.0001
0.0001 0.00001
inch system
0.0001 0.00001
Double values can be read for a machining center system or when radius
specification is used for the relevant axis of a lathe system.