B–61863E/15
1. SCREEN OPERATION
FOR FS16i/18i/21i/0i–B
PMC–SA1/SB7
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
841
In symbol/comment display/editing screen, you can edit maximum 16
characters of symbols. Other screens which shows the symbols can
display and handle the symbols up to following character length.
Screens
Max. display
character length
Search length Remark
Symbol/comment editing 16char. 16 char.
Ladder monitor/editing 7char. 16 char. 16 characters display is available in additional in-
formation line
Program list 6 char. 16 char.
Signal status 7 char. 16 char.
Cross reference 7 char. – 16 characters display is available in specifying ad-
dress (type 1) screen
Trace 7 char. 16 char. 9 characters display is available in setting screen
The symbol characters exceeding the displaying field are omitted in each
screen. Search function fully compares 16 characters in all screens which
have search function.
The following system keep relays are added.
Item Meaning PMC–SB7
EDIT ENABLE Allows editing the ladder program. K901.6
ALLOW PMC STOP Allows start /stop of ladder program. K902.2
TRACE START Starts the tracing automatically after
power turns on
K906.5
Please refer to ”2. SETTING FUNCTION” for detail.
1.2.2
Expansion of Symbol
Size
1.2.3
Addition of System