B–61863E/15
C. WINDOW FUNCTION DESCRIPTION
(PMC–NB/NB2/NB6)
APPENDIX
1397
[Hardware]
When general analog input data is read, one of the following hardware
items is required:
1 Sub–CPU board
2 Analog I/O module on the additional axis board
For details of the relationship between input numbers and connectors,
refer to the connection manual. When an NC controlled axis load current
is read, the hardware described above is not required.
[NC parameters]
When this function is used, the NC parameters listed below need to be set.
For details, refer to the parameter descriptions.
1 Bit 6 of parameter No. 1810 = 0 (A/D conversion is performed.)
2 Bit 0 of parameter No. 1811 = 1 (A/D conversion data is output in
high–speed mode.)
[Description]
The number of the tool group in which the tool number is cataloged is
read.
0
Function code
38
Completion code
—
Data length
—
Data number
0
Tool No.
Data area
(4 byte)
2
4
6
8
10
Set data
14
0
2
4
6
8
10
Read data
14
Function code
38
Completion code
Data length
4
Data number
Tool No.
Tool group No.
(4 byte)
NOTE
The data can be read only when the tool life management
data function is provided.
C.3.17
Reading the Tool Life
Management Data
(Tool Group Number)
(Low–speed Response)