5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
260
(a) Format specification
Specifies data length (1, 2, and 4 bytes) and the format for the
multiplier (constant or address).
Data length specification
0
Format specification
1 : 1 byte length data
2 : 2 bytes length data
4 : 4 bytes length data
0
0 : Constant data
1 : Address data
(b) Multiplicand address
Address containing the multiplicand.
(c) Multiplier data (address or constant)
Specification in (a) determines the format of the multiplier.
(d) Result output address
Specifies the address to contain the result of operation.
W1=0 : Operation correct
W1=1 : Operation incorrect
W1 goes on (W1=1) if the result of multiplication exceeds the specified
data length.
This register is set with data on operation. If register bit is on, they signify
the following operation data:
76543210
R9000
Overflow
Zero
Negative
5.38.4
Parameters
5.38.5
Error Output (W1)
5.38.6
Operation Output
Register (R9000)