B–61863E/15
5. LADDER DIAGRAM EDITOR
FUNCTION (PMC–SB7)
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
915
At Functional Instruction Data Table Editor screen, you can edit the
contents of data table that belongs to some functional instructions. To
reach this screen, at Net Editor screen, press [TABLE] soft key that is
displayed when the cursor is on the following functional instructions
which have a data table.
– Functional Instruction COD (SUB7)
– Functional Instruction CODB (SUB27)
(Function instruction DISP(SUB49) is not be able to use)
Following edit operations are available at this screen.
– Change the data table value. ”number” + ENTER key
– Change the data length. [BYTE], [WORD], [D.WORD]
(These soft keys can be operated only at Functional Instruction Data
Table Editor screen of Functional Instruction CODB.)
– Change the number of data [COUNT]
– Initialize all of data [INIT]
Fig. 5.8 Functional Instruction Data Table Editor screen
5.8
FUNCTIONAL
INSTRUCTION DATA
TABLE EDITOR
SCREEN