5. FUNCTIONAL INSTRUCTIONS
B–61863E/15
PMC SEQUENCE PROGRAM
280
Conform to the following instruction format. Variable data, i.e., any
numeric value of up to four BCD digits, can be displayed.
SUB49
ffff
ffff
Message characters
Message control address
Total number of steps in message data
ffff
Number of steps in one message data item
ffff
Message number
ffff
990m
VVVV
ffff
Variable data specification
Variable data address
Message number
Message characters
ffff
ffff
990m
VVVV
Message number
Variable data specification
Variable data address
Message characters
990m
VVVV
Variable data address
Variable data specification
Instruction format
NOTE
1 One step is used at variable data specification 990m.
2 The number of steps is the same for each message data
item. The number of characters to be displayed varies
according to the value specified for m.
3 Multiple variable data items can be used in one message
data item.
(1) Specifying variable data
Specifies the number of digits in the variable data.
(1xmx4)
Variable data
9 9 0 m
5.43.10
Variable Data Display
by Specifying Variable
Data