B–61863E/15
5. FUNCTIONAL INSTRUCTIONS
PMC SEQUENCE PROGRAM
307
(a) Execution command (ACT)
The contents of the execution command can be referenced by bit 1
at R9010.
(b) Control data address
The address where the control data is stored can be referenced in the
byte address format at R9012 or later.
(c) Process end output (W1)
The data output when the process terminates can be referenced by bit
1 at R9011.
R9010 97 96 95 94 93 92 91 90
R9011 97 96 95 94 93 92 91 90
R9012
R9014 Control data address of SUB91
R9026
Control data address of SUB97
Byte address
Execution command data
Process end output data
Control data address of SUB90
Reference the start condition (ACT) of the arbitrary function by bit 1 at
R9010. Reference the address at which the control data is stored in the
byte address format by the fields at R9012 and later. Set the end signal
(W1) of an arbitrary function in bit 1 at R9011. For example, to execute
the arbitrary function using SUB90, reference the start condition by
R9010.0. Reference the control data address in the byte address format
by R9012. Set the end signal at R9011.0.
5.48.2
Creating an Arbitrary
Function
5.48.2.1
Arbitrary Functional
Instruction and Interface
5.48.2.2
Use of the R Field
5.48.2.3
Creating an Arbitrary
Function