L. MIGRATION OF LADDER PROGRAMS
BETWEEN DIFFERENT MODELS
B–61863E/15
APPENDIX
1542
(Example)
N63000 P2;
N63002 P00000000;
N63003 P0;
N63004 P10;
N63006 P0;
N63010 P00000001;
N63011 P0;
N63012 P10;
N63014 P10;
(ii)Data Table
[Format]
N64xxx Pnnnnn;
N: The offset of the Data Table address plus 64000.
The range:
PMC–SA1/SA5: N64000 to N65859
PMC–SB5: N64000 to N66999
PMC–SB6: N64000 to N71999
P: The value of the Data Table address with signed decimal
numeric. The ranges of the value depend on the data type
of the Data Table and are from –128 to 127 with the
1–byte type, from –32768 to 32767 with the 2–byte type,
from –2147483648 to 2147483647 with the 4–byte type.
(Example)
N64000 P–128;
N64001 P100;
N64002 P0;
.......
N64010 P1000;
N64012 P–1;
.......
N64992 P50000000;
N64996 P50000000;
(1)Header
[Format]
%; (PMC=SB7,MSID=0)
PMC: PMC Series. In PMC–SB7, ”SB7” is output.
MSID: Reserve for FANUC. Always MSID=0.
(2)Timer (T)
[Format]
N60xxxx Pnnnnn; Setting value of timer
N: The numbers of timer address plus 600000. The ranges are
from N600000 to N600498 and from N609000 to N609498.
P: The timer value with decimal numeric. The effective values
from N600000 to N600498 are from 0 to 32767. The
effective values from N609000 to N609498 are from 0 to 5.
L.3.2.3
Format for PMC–MODEL
SB7