Table 3.2.1 (a) Input signals whose addresses are fixed (Series 16/Series 18)
Address
Signal Symbol
When the I/O Link
is used
When the built–in
I/O card is used
T series Signal indicating that X–axis measurement position is reached XAE X4.0 X1004.0
Signal indicating that Z–axis measurement position is reached ZAE X4.1 X1004.1
Function B for directly entering the measurement value of tool
compensation in the positive X direction
+MIT1 X4.2 X1004.2
Function B for directly entering the measurement value of tool
compensation in the negative X direction
–MIT1 X4.3 X1004.3
Function B for directly entering the measurement value of tool
compensation in the positive Z direction
+MIT2 X4.4 X1004.4
Function B for directly entering the measurement value of tool
compensation in the negative Z direction
–MIT2 X4.5 X1004.5
M series Signal indicating that X–axis measurement position is reached XAE X4.0 X1004.0
Signal indicating that Y–axis measurement position is reached YAE X4.1 X1004.1
Signal indicating that Z–axis measurement position is reached ZAE X4.2 X1004.2
Common Skip signal SKIP X4.7 X1004.7
Emergency stop signal *ESP X8.4 X1008.4
Deceleration signal for 1st axis reference position return *DEC1 X9.0 X1009.0
Deceleration signal for 2nd axis reference position return *DEC2 X9.1 X1009.1
Deceleration signal for 3rd axis reference position return *DEC3 X9.2 X1009.2
Deceleration signal for 4th axis reference position return *DEC4 X9.3 X1009.3
Deceleration signal for 5th axis reference position return *DEC5 X9.4 X1009.4
Deceleration signal for 6th axis reference position return *DEC6 X9.5 X1009.5
Deceleration signal for 7th axis reference position return *DEC7 X9.6 X1009.6
Deceleration signal for 8th axis reference position return *DEC8 X9.7 X1009.7
If the NC is a TT system, the signals for tool post 2 listed in Table 3.2.1
(b) are always assigned to the following addresses.
In addition, the system does not have the signals for tool post 1, DEC5
to DEC8 (X9.4 to X9.7).
Table 3.2.1 (b) Input signals whose addresses are fixed (TT) (Series 16/Series 18)
Address
Signal Symbol
When the I/O Link is
used
When the built–in
I/O card is used
TT Signal indicating that X–axis measurement position is reached XAE X13.0 X1013.0
series
Signal indicating that Z–axis measurement position is reached ZAE X13.1 X1013.1
Function B for directly entering the measurement value of tool
compensation in the positive X direction
+MIT1 X13.2 X1013.2
Function B for directly entering the measurement value of tool
compensation in the negative X direction
–MIT1 X13.3 X1013.3
Function B for directly entering the measurement value of tool
compensation in the positive Z direction
+MIT2 X13.4 X1013.4
Function B for directly entering the measurement value of tool
compensation in the negative Z direction
–MIT2 X13.5 X1013.5
Skip signal SKIP X13.7 X1013.7
Deceleration signal for 1st axis reference position return *DEC1 X7.0 X1007.0
Deceleration signal for 2nd axis reference position return *DEC2 X7.1 X1007.1
Deceleration signal for 3rd axis reference position return *DEC3 X7.2 X1007.2
Deceleration signal for 4th axis reference position return *DEC4 X7.3 X1007.3