B–61863E/15
3. PMC I/O SIGNAL DISPLAY AND
INTERNAL RELAY DISPLAY
(PMCDGN)
PMC OPERATION (CRT/MDI)
437
Title Data refers to the title of the sequence program created by the
machine tool builder.
They consist of the following ten items :
Machine tool builder name (32 characters)
Machine tool name (32 characters)
NC and PMC types (32 characters)
Sequence program number (4 characters)
Version (2 characters)
Sequence program drawing number (32 characters)
Date when the sequence program was created (16 characters)
Sequence program programmer (32 characters)
ROM programmer (32 characters)
Comment (32 characters)
In addition to the title display :
1) Series and version of the PMC control software.
2) Type of the PMC.
3) For Editing module or Editing card, the series and version.
4) Memory areas used for each sequence data, and execution time of
ladder program.
5) Type of PMC control module and PMC sequence program.
6) For the non-dividing system, the present, maximum and minimum
values for the execution time of ladder program.
NOTE
When a C board is installed in the Series 16i/18i, the title
data for C can be displayed. With the arrow keys [²] and
[³], the user can switch the display between the ladder title
and C title data.
To display the previous or next screen on the 9″ CRT/MDI, use the
<PAGE °> or <PAGE ±> key.
PMC TITLE DATA #1 MONIT RUN
PMC PROGRAM NO. : 1234
EDITION NO. : 12
PMC CONTROL PROGRAM
SERIES : 4063 EDITION : 08
(SERIES : 4065 EDITION : 08)
PMC TYPE CONTROL : RB3 PROGRAM : RB3
MEMORY USED : 007.8 KB
LADDER : 007.0 KB
SYMBOL : 000.0 KB
MESSAGE : 000.8 KB
SCAN TIME : 008 MS
SCAN MAX : 016 MS MIN : 008 MS
[TITLE ] [STATUS ] [ALARM ] [TRACE ] [ ]
Fig. 3.1 (a) Title data 1
3.1
DISPLAYING TITLE
DATA