B–61863E/15
6. SIGNAL TRACE
FUNCTION (PMC–SB7)
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
939
NOTE
1 The SAMPLING ADDRESS is outputted where there is a
setting.
Therefore, empty coloulm isn’t outputted for the item of
”ADDRESS”.
2 Nothing is outputted when a ”SYMBOL” and ”COMMENT”
aren’t established. Empty coloulm is outputted. Commas
are not omitted until the place where SAMPLING
ADDRESS is set.
D Data of the trace result
ID, Sampling Address1, Sampling Address 2,......
Number of Frame, Data1, Data2, Data3,......
:
:
ID String data.
”Data”.
Number of Frame Numerical data.
The position of the frame number ”0”
becomes a trigger formation position.
When a trigger isn’t concluded, the moment
when sampling stopped becomes ”0”.
Data Numerical data.
”0” or ”1”.
It is decided that data continue to EOF(END
OF FILE), and the data size isn’t set up.
Tracing result output example (A tab isn’t actually outputted though it is
inserted to make it easy to see.)
’PMC TRACE DATA’
’Edition’, 1
’Setting’, , ,
1, ’Sampling mode’,2, ’SIGNAL
TRANSITION’
2, ’Sampling resolution’,8, ’MSEC’
3, ’Sampling time’, 2000,
4, ’Stop condition’,3, ’TRIGGER’
5, ’Stop trigger address’, ’X10.0’, ’SYMBOL1’
6, ’Stop trigger mode’,1, ’RISING EDGE’
7, ’Stop trigger position’, 50(1250/2500),’%’
8, ’Sampling condition’,1, ’TRIGGER’
9, ’Sampling trigger address’, ’X10.1’, ’SYMBOL2’
10, ’Sampling trigger mode’,3, ’BOTH EDGE’
’Address’, ’R0000.0’, ’R0000.1’, ’R0000.2’, ’R0000.3’, ’R0000.4’,
’R0000.5’, ’R0000.6’, ’R0000.7’, ’R0001.0’, R0002.0’
’Symbol’, ’ZRN_M’,, ,’*SPA1’, ’*SPA2,
’MX–RD’, ’RSTN’, ’RSTMA’, ’MO1X’, ’MO2X’