B–61863E/15
B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
APPENDIX
1277
Power
Mate
FS20 FS18 FS16
∆ ∆ ∆
∆ : The support is decided by CNC series
: No support
CAUTION
The unexpected disturbance torque detection function
option is required. For detailed settings of parameters and
so forth, refer to the description of unexpected disturbance
torque detection in the connection manual (functions).
(1) servo axis
[Description ]
The load torques except a necessary torque for acceleration/ deceleration
of the digital servo axis are read.
[Input data structure]
Top address + 0
+2
+4
+6
+8
+10
(Function code)
211
(Completion code)
–
(Need not to be set)
(Data length)
–
(Need not to be set)
(Data number)
0
(Data attribute)
M
(M=Axis number)
(Data area)
–
(Need not to be set)
+12
M=1 to n : Estimate disturbance torque data
for specific axis. “n” is the axis
number.
M= – 1 : Estimate disturbance torque data
for all axes.
B.4.62
Reading the Estimate
Disturbance Torque
Data