2. SETTING FUNCTION
B–61863E/15
FS16i/18i/21i/0i–B PMC–SA1/SB7 MANIPULATION
860
#7
DTBLDSPK17
or
K900
#6 #5
TRCSTAT
#4
MEMINP
#3 #2
AUTORUN
#1
PRGRAM
#0
LADMASK
#7 DTBLDSP 0 : The PMC parameter data table control screen is displayed.
1 : The PMC parameter data table control screen is not displayed.
#5 TRCSTAT 0 : Starts trace function when the execution soft key is pressed.
1 : Starts trace function automatically at power on.
: This flag is effective on PMC–SA1.
#4 MEMINP 0 : The forcing function and override function are disabled.
1 : The forcing function and override function are enabled.
#2 AUTORUN 0 : The sequence program automatically starts at power on.
1 : The sequence program starts when the [RUN]soft key is pressed.
#1 PRGRAM 0 : The built–in programmer function does not operate.
(Also, the programmer menu is not displayed)
1 : The built–in programmer function operates.
(The programmer menu is displayed.)
#0 LADMASK 0 : Functions which have the sequence program display are enabled.
1 : Functions which have the sequence program display are disabled.
#7
IGNDINTK18
or
K901
#6
EDITLAD
#5
CHKPRTY
#4
CALCPRTY
#3
TRNSRAM
#2
TRGSTAT
#1
DBGSTAT
#0
IGNKEY
#7 IGNDINT 0 : The system initializes the LCD when the screen is switched to the
PMCMDI screen.
1 : The system does not initialize the LCD when the screen is switched to
the PMCMDI screen.
: This flag is effective when PMC C program is used. This flag is used
to determine whether the system initializes the LCD or not when the
screen is switched to PMCMDI screen. When this flag is on, PMC C
program must initialize the LCD.
#6 EDITLAD 0 : Editing of sequence program is disabled.
1 : Editing of sequence program is enabled.
#5 CHKPRTY 0 : The system ROM and program ROM/RAM are checked for parity
errors.
1 : The system ROM and program ROM/RAM are not checked for parity
errors.
#4 CALCPRTY 0 : The built–in programmer function performs RAM parity calcuration.
1 : The built–in programmer function does not perform RAM parity
calcuration.
#3 TRNSRAM 0 : A ladder program is not automatically sent to the backup RAM after
on–line editing is completed.
1 : A ladder program is automatically sent to the backup RAM after
on–line editing is completed.
2.8
KEEP RELAYS USED
IN THE SYSTEM