B. WINDOW FUNCTION DESCRIPTION
(PMC–PA1/PA3/SA1/SA2/SA3/SA5/SB/
SB2/SB3/SB4/SB5/SB6/SB7/SC/SC3/SC4)
B–61863E/15
APPENDIX
1334
[Completion codes]
0 : Reading the CNC alarm status has terminated normally.
[Output data structure]
Top address +0
+2
+4
+6
+8
+10
(Function code)
186
(Completion code)
–
(See the explanation of the
completion code)
(Data length)
2
(Data number)
0
(Same as input data)
(Data attribute)
0
(Same as input data)
Alarm status information
(See below.)
+12
Alarm status information
bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Bit 0: P/S alarm 100 (PS1)
(The alarm write enable setting PWE is set to 1.)
Bit 1: P/S alarm 000 (PS2)
(Turn the power off once. A written parameter may cause
this alarm.)
Bit 2: P/S alarm 101 (PS3)
(The part program storage area is disordered. If the power
to the CNC is turned off during part program editing or
machining program reading, this alarm occurs. To release
this alarm, press the RESET key while holding the PROG
key down.)
Bit 3: A P/S alarm other than the above occurs. (PS) (Up to 255)
Bit 4: Stroke limit alarm (OTS)
Bit 5: Overheat alarm (OH)
Bit 6: Servo alarm (SV)
Bit 7: Not used
Bit 8: APC alarm (APAL)
Bit 9: Spindle alarm (SPA)
Bit 10: P/S alarm having a number 5000 or after (PS_2)
Bits 11 to 15: Not used