C. WINDOW FUNCTION DESCRIPTION
(PMC–NB/NB2/NB6)
B–61863E/15
APPENDIX
1424
NOTE
1. The valid area of data number m is as follows:
0 ≤ m ≤ (524288 × 1/a × 1/b) – 1
1 : the number of the axes for Fine Torque Sensing is 1
for a = 2 : the number of the axes for Fine Torque Sensing is 2
4 : the number of the axes for Fine Torque Sensing is 3 or 4
1 : sample data saving function is disabled
b =
2 : sample data saving function is enabled
The valid area of the number of data n is as follows:
1 ≤ n ≤ 120
2. When data number m which is in the valid range exceeds the number of actually stored data
items, ”0” is read as data length and no data is read. The function completes normally.
Ex.) In case that the number of target axes is 2 and the sample data store function is enabled,
the data numbers are valid in the range between 0 and 13107. However, if an attempt is
made to read data from data number m ”131020” when the number of actually stored data
items is 131000 (the data number from 0 to 130999), ”0” is read as data length and no data
is read. The function completes normally.
(Example 1 in figure below)
3. When data number m is within the number of actually stored data items, and the number
”m+n–1” exceeds the number of actually stored data items, data of the stored data items is read.
The function completes normally.
In this case, double of the number of read data items is read as data length.
Ex.) If an attempt is made to read number of data items n ”120” from data number m ”130900”
under the same conditions as in the example above, the data number from 130900 to
130999 is read and ”200” is read as data length.
(Example 2 in figure below)
Also if an attempt is made to read number of data items n ”120” from data number m
130990 under the same conditions as in the example above, the data number from 130990
to 130999 is read, and ”20”is read as data length.
(Example 3 in figure below)
Data number vallid range
Range of actually stored data
0 131000 131071
Specified range (Ex. 1)
Specified range (Ex. 2)
Specified range (Ex. 3)
Reading range
Reading range