5. FUNCTIONAL INSTRUCTIONSPMC SEQUENCE PROGRAM
175
For PMC–SB7 :
Timer accuracy Setting number The range of setting time (Note) Margin of error
8msec 0 8msec to about 262.1sec 0 to + Level 1 Sweep Interval
48msec 1 48msec to about 26.2 min 0 to + Level 1 Sweep Interval
1sec 2 1sec to about 546 min 0 to + Level 1 Sweep Interval
10sec 3 10sec to about 91 h 0 to + Level 1 Sweep Interval
1min 4 1min to about 546 h 0 to +1sec
1msec 5 1msec to about 32.7 sec 0 to + Level 1 Sweep Interval
10msec 6 10msec to about 327.7 sec 0 to + Level 1 Sweep Interval
100msec 7 100msec to about 54.6 min 0 to + Level 1 Sweep Interval
NOTE
The range of the value is 0 to 32767.
Sets the first address of the timer set time field.
The continuous 2–byte memory space is required for the timer set time
field.
Field D is normally used as this field.
Timer set time + 0
Time : Timer set time
(1 to 32,767)
Timer set time + 1
TIME
The timer set time is converted into the binary value in 8 ms (48 ms) units.
The timer set time is shown as follows:
8 ms 8 to 262,136 ms
48 ms 48 to 1,572,816 ms
1 s 1 to 32,767s
10 s 1 to 327,670s
1 m 1 to 32,767m
Set the start address of a timer register area.
A timer register area must be allocated to a continuous four–byte memory
area starting from the set address. Normally, the R area is used as a timer
register area. This area should be used by the PMC system, and therefore
should not be used by the sequence program.
Timer register + 1
Timer register
Timer register + 2
Timer register + 3
Timer register + 0
5.6.5
Timer Set Time
Address
5.6.6
Timer Register
Address